Portable Combustible gas detectors Uses: Suitable for places where methane concentration needs to be detected
The main technical parameters: | |
Detection gas: | methane (CH4), etc. |
Sensor type: | catalytic combustion |
Range: | 0-100% LEL |
Basic error: | ±5% FS |
Resolution: | 1% LEL |
Response time: | ≤30s |
Display mode: | LCD display |
Alarm set point: | adjustable |
Alarm mode: | sound and light alarm (alarm, fault, undervoltage) |
Reading: | instantaneous value, maximum value |
Battery: | 4.8VDC, rechargeable battery pack |
Battery working time: | continuous use time > 8 hours (normal temperature) |
Explosion-proof grade: | Exia IIC |
Working temperature: | -20 ° C -70 ° C |
Working humidity: | ≤93%RH (no condensation) |
Sensor life: | 2 years |
Size: | 80mm*164mm*30mm |
Weight: | 230g |